Ite switching power supply single output 50 w 24 v closed framers-50-24
REF : RS5024
€20.70
Features universal AC input / full range cooling: by free air convection LED indicator for power on 100 % full load burn-in test using 105 °C long-life electrolytic capacito
: 1 Item
Emplacement : -()R4L3
Security policy
Delivery policy
Terms of Sales
Features
universal AC input / full range
cooling: by free air convection
LED indicator for power on
100 % full load burn-in test
using 105 °C long-life electrolytic capacitors
withstands 300 VAC surge input for 5 seconds
high operating temperature up to 70 °C
withstands 5G vibration test
no load power consumption < 0.5 W
high efficiency, long life and high reliability
3 years warranty
protection against: short circuit / overload / overvoltage
FOR PROFESSIONAL USE
This device must be installed by a qualified person.
Specifications
output:
DC voltage: 24 V
rated current: 2.2 A
current range: 0-2.2 A
rated power: 52.8 W
ripple & noise (max.): 120 mVp-p
voltage adj. range: 22-27.2 V
voltage tolerance: ± 1.0 %
line regulation: ± 0.5 %
load regulation: ± 0.5 %
setup, rise time:
500 ms, 30 ms / 230 VAC
1200 ms, 30 ms / 115 VAC at full load
hold up time (typ.):
60 ms / 230 VAC
14 ms / 115 VAC at full load
input:
voltage range:
88-264 VAC
125-373 VDC
withstands 300 VAC surge for 5 s
frequency range: 47-63 Hz
efficiency (typ.): 88 %
AC current (typ.):
1.3 A / 115 VAC
0.8 A / 230 VAC
inrush current (typ.): cold start 33 A / 230 VAC
leakage current: < 2 mA / 240 VAC
protection:
overload:
110-150 % rated output power
protection type: hiccup mode, recovers automatically after fault condition is removed
overvoltage:
27.6-32.4 V
protection type: hiccup mode, recovers automatically after fault condition is removed
environment:
operating temperature: -25 to +70 °C
operating humidity: 20-90 % RH non-condensing
storage: -40 to +85 °C, 10-95 % RH
temperature coefficient: ± 0.03 %/°C (0-50 °C)
vibration: 10-500 Hz, 5G 10 min/1 cycle, period for 60 min each along X, Y, Z axes
safety & EMC:
safety standards: UL60950-1, TUeV EN60950-1 approved
withstand voltage:
input to output: 3 kVAC
input to ground: 2 kVAC
output to ground: 0.5 kVAC
isolation resistance: input to output, input to ground, output to ground: 100 Mohm / 500 VDC / 25 °C / 70 % RH
EMC emission: compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3
EMC immunity: compliance to EN61000-4-2,3,4,5,6,8,11; EN61000-6-2 (EN50082-2), heavy industry level, criteria A
other:
MTBF: min. 228,000 h, MIL-HDBK-217F (25 °C)
dimensions (L x W x H): 99 x 97 x 36 mm
weight: 410 g
FOR PROFESSIONAL USE ONLY
This device must be installed by a qualified person
RETRAIT DANS NOTRE MAGASIN A TOULOUSE Our shop is open to collect your order from 9am to 1pm and from 2pm to 6pm from Monday to Friday
Free!
POSTE LETTRE SUIVIE
POSTE LETTRE SUIVIE 3 JOURS
€3.74
Colissimo Points de retrait Delivery at post office, Pickup points & lockers
€6.59
Colissimo Domicile avec signature Home delivery with proof of delivery
€8.81
Return
Free return within 14 days