60w single output industrial din rail power supply 12v 4.5a for professional use only dr-60-12 velleman - 5

60w single output industrial din rail power supply 12v 4.5a for professional use only dr-60-12

REF : DR6012

€22.99
Features universal AC input / full range protection against: short circuit / overload / overvoltage cooling: free air convection can be installed on DIN rail TS-35/7.5 or 15

Volume discounts

5
€21.84
10
€20.69
20
€18.39
: 2 Items

Emplacement : -()R4I5


Features

universal AC input / full range
protection against: short circuit / overload / overvoltage
cooling: free air convection
can be installed on DIN rail TS-35/7.5 or 15
UL 508 (industrial control equipment) approved
isolation class II
LED indicator for power on
100 % full load burn-in test
3 years warranty
FOR PROFESSIONAL USE
This device must be installed by a qualified person.

Specifications

output:
DC voltage: 12 V
rated current: 4.5 A
current range: 0-4.5 A
rated power: 54 W
ripple & noise (max.): 120 mVp-p
voltage adj. range: 11.1-13.2 V
voltage tolerance: ± 1.0 %
line regulation: ± 1.0 %
load regulation: ± 1.0 %
setup, rise time: 100 ms, 30 ms / 230 VAC 200 ms, 30 ms / 115 VAC at full load
hold up time (typ.): 100 ms / 230 VAC 23 ms / 115 VAC at full load
input:
voltage range: 88-264 VAC 124-370 VDC
frequency range: 47-63 Hz
efficiency (typ.): 82 %
AC current (typ.): 1.2 A / 115 VAC 0.8 A / 230 VAC
inrush current (typ.): cold start 18 A / 115 VAC 36 A / 230 VAC
protection:
overload:
105-160 % rated output power
protection type: constant current limiting, recovers automatically after fault condition is removed
overvoltage:
13.8-16.2 V
protection type: shut down output voltage, re-power on to recover
environment:
operating temperature: -20 to +60 °C
operating humidity: 20-90 % RH non-condensing
storage: -40 to +85 °C, 10-95 % RH
temperature coefficient: ± 0.03 %/°C (0-50 °C)
vibration: 10-500 Hz, 2G 10min/1cycle, period for 60 min each along X, Y, Z axes; mounting: compliance to IEC60068-2-6
safety & EMC:
safety standards: UL60950-1, TUV EN60950-1 approved, design refer to EN50178
withstand voltage: input to output: 3 kVAC
isolation resistance: input to output: 100 Mohm / 500 VDC / 25 °C / 70 % RH
EMC emission: compliance to EN55011, EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC immunity: compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
others:
MTBF: min. 216,200 h, MIL-HDBK-217F (25 °C )
dimensions (L x W x H): 78 x 93 x 56 mm
packing: 0.3 kg; 48 pcs / 15.4 kg / 1.02 ft³
FOR PROFESSIONAL USE ONLY
This device must be installed by a qualified person
velleman
DR6012
2 Items

No customer reviews for the moment.

RETRAIT DANS NOTRE MAGASIN A TOULOUSE
RETRAIT DANS NOTRE MAGASIN A TOULOUSE
Our shop is open to collect your order from 9am to 1pm and from 2pm to 6pm from Monday to Friday
Free!
Colissimo Points de retrait
Colissimo Points de retrait
Delivery at post office, Pickup points & lockers
€6.63
Colissimo Domicile avec signature
Colissimo Domicile avec signature
Home delivery with proof of delivery
€8.83
Return
Free return within 14 days

Produits dans la même catégorie

New Account Register

Already have an account?
Log in instead Or Reset password