Features:
Universal AC input/ full range
Protections: Short circuit/ Over load/ Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Isolation classII
LED indicator for power on
100% full load burn-in test
SPECIFICATIONS
OUTPUT
Model DR-15-5
DC Voltage 5V
Rated Current 2.4A
Current Range 0-2.4A
Rated Power 15W
Ripple & Noise 80mVp-p
Voltage Adj. Range -5%,+10%
Voltage Tolerance ±2%
Setup, Rise, Hold Up Time
1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load 70ms/230VAC 16ms/115VAC at full load
INPUT
Voltage Range
85 ~ 264VAC 120 ~ 370VDC
AC Current 0.48A/230VAC
Efficiency 74%
Inrush Current
COLD START 35A/115VAC 65A/230VAC
PROTECTION
Over Load 105%~160%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 115%~135%
Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENT
Working Temp., Humidity -10C~+60C; 20%~90%RH
Storage Temp., Humidity -40C~+85C; 10%~95%RH
Temp. Coefficient ±0.03%/C(0~50C)
Vibration
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY
Withstand Voltage I/P-O/P: 3KVAC
Isolation Resistance I/P-O/P: 100M Ohms / 500VDC
STANDARD
Safety Standard
Design refer to UL60950-1,TUV EN60950-1,EN50178
EMC Standard
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3
OTHERS
Dimension 25*93*56mm(L*W*H)
Weight 0.18Kg
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1? & 47? Parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed