Supply 110v 220v 5v dc 3a 15va din rail dr-stabilized power supply 230v 240v 15-5 220vac 85-264V phoenix contact - 2

Supply 110v 220v 5v dc 3a 15va din rail dr-stabilized power supply 230v 240v 15-5 220vac 85-264V

REF : DR155

€95.50
Features:Universal AC input/ full rangeProtections: Short circuit/ Over load/ Over voltageCooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15Isolation classIILED in

Volume discounts

5
€90.73
10
€85.95
20
€76.40
50
€71.63
100
€66.85
200
€62.08
500
€57.30
1000
€52.53
Disponible sur commande. Délais nous contacter.

Emplacement :


Features:
Universal AC input/ full range
Protections: Short circuit/ Over load/ Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
Isolation classII
LED indicator for power on
100% full load burn-in test

SPECIFICATIONS
OUTPUT
Model DR-15-5
DC Voltage 5V
Rated Current 2.4A
Current Range 0-2.4A
Rated Power 15W
Ripple & Noise 80mVp-p
Voltage Adj. Range -5%,+10%
Voltage Tolerance ±2%
Setup, Rise, Hold Up Time

1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load 70ms/230VAC 16ms/115VAC at full load

INPUT
Voltage Range
85 ~ 264VAC 120 ~ 370VDC
AC Current 0.48A/230VAC

Efficiency 74%
Inrush Current
COLD START 35A/115VAC 65A/230VAC

PROTECTION
Over Load 105%~160%

Protection type: Constant current limiting, recovers automatically after fault condition is removed

Over Voltage 115%~135%

Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENT
Working Temp., Humidity -10C~+60C; 20%~90%RH
Storage Temp., Humidity -40C~+85C; 10%~95%RH
Temp. Coefficient ±0.03%/C(0~50C)

Vibration
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes

SAFETY
Withstand Voltage I/P-O/P: 3KVAC
Isolation Resistance I/P-O/P: 100M Ohms / 500VDC
STANDARD
Safety Standard
Design refer to UL60950-1,TUV EN60950-1,EN50178

EMC Standard
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3
OTHERS
Dimension 25*93*56mm(L*W*H)
Weight 0.18Kg

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1? & 47? Parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed
DR155

No customer reviews for the moment.

RETRAIT DANS NOTRE MAGASIN A TOULOUSE
RETRAIT DANS NOTRE MAGASIN A TOULOUSE
Our shop is open to collect your order from 9am to 1pm and from 2pm to 6pm from Monday to Friday
Free!
Colissimo Points de retrait
Colissimo Points de retrait
Delivery at post office, Pickup points & lockers
€5.70
Colissimo Domicile avec signature
Colissimo Domicile avec signature
Home delivery with proof of delivery
€7.98
Return
Free return within 14 days

You might also like

Produits dans la même catégorie

New Account Register

Already have an account?
Log in instead Or Reset password