Multimeter digital lcd 3½ voltage current resistance temperature capacitance frequency measurement of diodes DVM895
REF : DVM895_1
€66.58
:
2 Items
Emplacement :
DIGITAL MULTIMETER - CAT. III 600V / CAT IV 300V - 1999 POINTS DVM895 automatic polarity indication
Multimeter digital lcd 3½ voltage current resistance temperature capacitance frequency measurement of diodes
Characteristics
CAT III 600V / CAT IV 300V
automatic polarity indication
automatic zero adjustment
voltage measurements: 600 VAC and 600 VDC max.
current measurements: DC 15 A and AC 15 A max.
resistance measurements: 200 MOhm max.
capacity measurements: 200 μF max.
thermocouple measuring range type K: -50 ° C to 800 ° C
frequency measurements: 20 kHz
with separate test leads (incl.): TLM72: PVC MEASURING CORD SET - CAT IV 600 V - 15 A - 18 AWG - LENGTH 75 cm
degree of pollution 2
Specifications
DC voltage: 0-200mV / 2V / 20V / 200V / 600V
basic accuracy: ± (0.5% of reading + 2 digits), ± (0.8% of reading + 2 digits) for 600 V range
input impedance: 10 MOhm
input max .: 600 V
overload protection: 600V DC or AC rms
AC voltage: 0-2V / 20V / 200V / 600V
basic accuracy: ± (0.8% of reading + 3 digits), ± (1.2% of reading + 3 digits) for 600 V range
input impedance: 1MB for 2V range, 10MB for other ranges
frequency range: 40-500 Hz
Max input: 600 V DC or AC rms
DC current: 200 μA / 2 mA / 20 mA / 200 mA / 15 A
basic accuracy: ± (1.2% of reading + 2 digits), ± (1.5% of reading + 2 digits) for 200mA range, ± (2.0% of reading + 3 digits) for 15A range
overload protection: fuse 500 mA / 600 V, 15 A / 600 V
AC current: 2 mA / 20 mA / 200 mA / 15 A
basic accuracy: ± (1.5% of reading + 3 digits), ± (2.0% of reading + 3 digits) for 200mA range, ± (2.5% of reading + 5 digits) for 15A range
overload protection: fuse of 500 mA / 600 V, 15 A / 600 V
frequency range: 40-500 Hz
resistance: 0-200 Ohm / 2 kOhm / 20 kOhm / 200 kOhm / 2 MOhm / 20 MOhm / 200 MOhm
basic accuracy: ± (1.0% of reading + 3 digits) for 200 Ohm range, ± (1.0% of reading + 2 digits) for range of 2 KOhm to 2 Mohm, ± (1.5% of reading + 3 digits) for 20 MOhm range, ± (5.0% of reading + 5 digits) for 200 MOhm range
overload protection: 600 VDC for AC rms
capacity: 2000 pF / 20 nF / 200 nF / 2 μF / 200 μF
basic accuracy: ± (2.5% of reading + 10 digits) for 2000 pF range, ± (2.5% of reading + 5 digits) for range of 20nF to 20 μF, ± (5.0% of reading + 10 digits) ) for 200 μF range
overload protection: 500 mA / 600 V fuse
temperature: -50-150 ° C / 150-800 ° C
basic accuracy: ± (3 ° C + 3 digits) for range of -50-150 ° C, ± (3% + 3 digits) for range of 150-800 ° C
overload protection: 500 mA / 600 V fuse
NiCr-NiSi sensor
K thermocouple probe: included
frequency: 20 kHz
basic accuracy: ± (2.0% of reading + 5 digits)
overload protection: 600 VDC or AC rms
sensitivity: sine wave 0.5 V rms
battery test: no
continuity buzzer: built-in buzzer retains when resistance is less than 50 Ohm
test voltage: ± 3 V
diode measurement: measures the direct voltage of the diodes
test voltage: ± 3 V (DC reverse voltage)
off-beach indication: yes
buzzer of continuity: yes
diode test: yes
low battery indication: yes
max display: 3 1/2
LCD display:
dimensions: 62 x 36 mm
figures: max. 1999
range selection: manual
data retention: no
backlight: yes
dimensions: 190 x 100 x 40 mm
weight (with battery): 300 g
power supply: 9V 6F22 (incl.)
automatic shutdown: yes
service environment:
temperature: 0 ° C to 40 ° C (32 to 104 ° F)
humidity: <80% (non-condensing)
storage environment:
temperature: -20 ° C to 60 ° C (-4 to 140 ° F)
humidity: <90% (non-condensing)
fuse:
F0.5 A / 600 V 5 x 20 mm
F15A / 600 V 5 x 20 mm
measuring probe: CAT III 1000V / CAT IV 600V, 15A, L = 75cm
IP rating: IP20
Multimeter digital lcd 3½ voltage current resistance temperature capacitance frequency measurement of diodes
Characteristics
CAT III 600V / CAT IV 300V
automatic polarity indication
automatic zero adjustment
voltage measurements: 600 VAC and 600 VDC max.
current measurements: DC 15 A and AC 15 A max.
resistance measurements: 200 MOhm max.
capacity measurements: 200 μF max.
thermocouple measuring range type K: -50 ° C to 800 ° C
frequency measurements: 20 kHz
with separate test leads (incl.): TLM72: PVC MEASURING CORD SET - CAT IV 600 V - 15 A - 18 AWG - LENGTH 75 cm
degree of pollution 2
Specifications
DC voltage: 0-200mV / 2V / 20V / 200V / 600V
basic accuracy: ± (0.5% of reading + 2 digits), ± (0.8% of reading + 2 digits) for 600 V range
input impedance: 10 MOhm
input max .: 600 V
overload protection: 600V DC or AC rms
AC voltage: 0-2V / 20V / 200V / 600V
basic accuracy: ± (0.8% of reading + 3 digits), ± (1.2% of reading + 3 digits) for 600 V range
input impedance: 1MB for 2V range, 10MB for other ranges
frequency range: 40-500 Hz
Max input: 600 V DC or AC rms
DC current: 200 μA / 2 mA / 20 mA / 200 mA / 15 A
basic accuracy: ± (1.2% of reading + 2 digits), ± (1.5% of reading + 2 digits) for 200mA range, ± (2.0% of reading + 3 digits) for 15A range
overload protection: fuse 500 mA / 600 V, 15 A / 600 V
AC current: 2 mA / 20 mA / 200 mA / 15 A
basic accuracy: ± (1.5% of reading + 3 digits), ± (2.0% of reading + 3 digits) for 200mA range, ± (2.5% of reading + 5 digits) for 15A range
overload protection: fuse of 500 mA / 600 V, 15 A / 600 V
frequency range: 40-500 Hz
resistance: 0-200 Ohm / 2 kOhm / 20 kOhm / 200 kOhm / 2 MOhm / 20 MOhm / 200 MOhm
basic accuracy: ± (1.0% of reading + 3 digits) for 200 Ohm range, ± (1.0% of reading + 2 digits) for range of 2 KOhm to 2 Mohm, ± (1.5% of reading + 3 digits) for 20 MOhm range, ± (5.0% of reading + 5 digits) for 200 MOhm range
overload protection: 600 VDC for AC rms
capacity: 2000 pF / 20 nF / 200 nF / 2 μF / 200 μF
basic accuracy: ± (2.5% of reading + 10 digits) for 2000 pF range, ± (2.5% of reading + 5 digits) for range of 20nF to 20 μF, ± (5.0% of reading + 10 digits) ) for 200 μF range
overload protection: 500 mA / 600 V fuse
temperature: -50-150 ° C / 150-800 ° C
basic accuracy: ± (3 ° C + 3 digits) for range of -50-150 ° C, ± (3% + 3 digits) for range of 150-800 ° C
overload protection: 500 mA / 600 V fuse
NiCr-NiSi sensor
K thermocouple probe: included
frequency: 20 kHz
basic accuracy: ± (2.0% of reading + 5 digits)
overload protection: 600 VDC or AC rms
sensitivity: sine wave 0.5 V rms
battery test: no
continuity buzzer: built-in buzzer retains when resistance is less than 50 Ohm
test voltage: ± 3 V
diode measurement: measures the direct voltage of the diodes
test voltage: ± 3 V (DC reverse voltage)
off-beach indication: yes
buzzer of continuity: yes
diode test: yes
low battery indication: yes
max display: 3 1/2
LCD display:
dimensions: 62 x 36 mm
figures: max. 1999
range selection: manual
data retention: no
backlight: yes
dimensions: 190 x 100 x 40 mm
weight (with battery): 300 g
power supply: 9V 6F22 (incl.)
automatic shutdown: yes
service environment:
temperature: 0 ° C to 40 ° C (32 to 104 ° F)
humidity: <80% (non-condensing)
storage environment:
temperature: -20 ° C to 60 ° C (-4 to 140 ° F)
humidity: <90% (non-condensing)
fuse:
F0.5 A / 600 V 5 x 20 mm
F15A / 600 V 5 x 20 mm
measuring probe: CAT III 1000V / CAT IV 600V, 15A, L = 75cm
IP rating: IP20
No customer reviews for the moment.
RETRAIT DANS NOTRE MAGASIN A TOULOUSE
Our shop is open to collect your order from 9am to 1pm and from 2pm to 6pm from Monday to Friday
Free!
Colissimo Points de retrait
Delivery at post office, Pickup points & lockers
€6.63
Colissimo Domicile avec signature
Home delivery with proof of delivery
€8.83
Return
Free return within 14 days