Detector approved surface mounting nc magnetic contact alarm detector alarm sensor switches magnetic door sensors
REF : 460FR
€49.92
The 1640 is approved NFA2P (N° 000023-01). This contact, whose case is made out of aluminium, has been specially designed for use on steel shutters and doors. The 1640 detects an opening of about 15m
: 1 Item
Emplacement : SUR COMMANDE RJ2 EGALE 460FRA R6J3
Security policy
Delivery policy
Terms of Sales
Dimension contact 19x79x13mm . Dimension magnet 19x79x13mm . Weight 145gr
WIDE OPEN SPACE SENSOR WIRE 460
. Wired magnetic sensor opening wide spacing
. Application Indoor / Outdoor. Ideal metal door
Reference: DO460-RA opening magnetic detector 460 via MG6250 Compatible DCTXP2
aluminum
Application Indoor / Outdoor
Door type metal garage door and sectional
Lxlxép Dimensions: 78x19x12 mm. Magnet: 78x19x12 mm
Cable: 3.00 m. This magnetic contact is mounted projection.
Detects an opening of about 30mm.
Exit the NC contact.
Current maximum authorized 500mA/12Vcc
NFA2P
WIDE OPEN SPACE SENSOR WIRE 460
. Wired magnetic sensor opening wide spacing
. Application Indoor / Outdoor. Ideal metal door
Reference: DO460-RA opening magnetic detector 460 via MG6250 Compatible DCTXP2
aluminum
Application Indoor / Outdoor
Door type metal garage door and sectional
Lxlxép Dimensions: 78x19x12 mm. Magnet: 78x19x12 mm
Cable: 3.00 m. This magnetic contact is mounted projection.
Detects an opening of about 30mm.
Exit the NC contact.
Current maximum authorized 500mA/12Vcc
NFA2P
| Rules mount magnetic contacts strong> td> tr> tbody> table> opening contact consists of a magnet and the magnetic field creating a contact whose state is modified by the presence of this field. in the air or neutral materials (wood, aluminum, plaster ...) the magnetic field is evenly distributed around the magnet. near ferromagnetic material (steel, soft iron) the magnetic field of the magnet is fully attracted and captured by this material and no longer acts in other directions. therefore it is necessary to remove enough magnets and magnetic media contacts using special spacers. To verify that material is ferromagnetic or not, use the magnet contact. If there is attraction between the magnet material, it is ferromagnetic. |
RETRAIT DANS NOTRE MAGASIN A TOULOUSE Our shop is open to collect your order from 9am to 1pm and from 2pm to 6pm from Monday to Friday
Free!
POSTE LETTRE SUIVIE
POSTE LETTRE SUIVIE 3 JOURS
€3.74
Colissimo Points de retrait Delivery at post office, Pickup points & lockers
€5.65
Colissimo Domicile avec signature Home delivery with proof of delivery
€7.93
Return
Free return within 14 days